EmStat4S Potentiostat/Galvanostat/EIS

  • Àü¾Ð ¹üÀ§ : ¡¾3V (LR) or ¡¾6V (HR)
  • Àü·ù ¹üÀ§ : 1 nA to 10 mA (LR) or 100 nA to 100 mA (HR)
  • Åë½Å ¹æ½Ä : USB powered
  • Description

    Specifications

    Techniques 

    Software

    Downloads

     

    Description

    EmStat4S´Â ÀÓÇÇ´ø½º ½ÇÇèÀÌ °¡´ÉÇÑ ÈÞ´ë¿ë Àåºñ·Î Á¦Ç° Å©±â°¡ ÀÛ¾Æ ÇöÀå¿ë ¶Ç´Â ºñÁ¼Àº ½ÇÇè½Ç¿¡ ÀûÇÕÇÕ´Ï´Ù.
    ´Ù¾çÇÑ Àü±âÈ­ÇÐ ½ÇÇè Å×Å©´ÐÀ» Áö¿øÇϸç Àü·ù ¹üÀ§¿¡ µû¶ó 2°¡Áö ¹öÁ¯(LR/HR)ÀÌ ÀÖ½À´Ï´Ù.
     

    »ç¿ë °¡´ÉÇÑ ±¸¼º

    EmStat4S´Â´Â Àü¾Ð, Àü·ù¿Í EIS »ç¾ç¿¡ µû¶ó ¾Æ·¡ ¸ðµ¨ ¹øÈ£·Î ºÐ·ùµË´Ï´Ù.

     

    EIS ¾øÀ½ [F0]

    EIS ÃÖ´ë 200 kHz [F1]

    EmStat4 LR
    Àü¾Ð »ç¾ç ¡¾ 3V
    Àü·ù ¹üÀ§ 1 nA to 10 mA

    C-ES4S-LR.F0

    C-ES4S-LR.F1

    EmStat4 HR
    Àü¾Ð »ç¾ç ¡¾ 6V
    Àü·ù ¹üÀ§ 100 nA to 100 mA

    C-ES4S-HR.F0

    C-ES4S-HR.F1


    EmStat4S LR or HR ±¸¼ºÇ° :

    • EmStat4S LR or HR 
    • USB-C cable
    • USB-C splitter cable for extra power (EmStat4S HR only)
    • Sensor cable
    • 4 or 5 croc clips
    • Dummy Cell
    • PSTrace software for Windows (on USB drive)
    • Manual (hardcopy)
    • Quick Start document
    • Calibration report

    EmStat4S


    Specifications

    EM4S




    Techniques

    EmStat4S LR or HR¿¡¼­ Áö¿øµÇ´Â Å×Å©´ÐÀº ´ÙÀ½°ú °°½À´Ï´Ù.

    Voltammetric techniques :

    • Linear sweep voltammetry (LSV)
    • Cyclic Voltammetry (CV)
    • Fast Cyclic Voltammetry (FCV) * ´ÙÀ½ ¼ÒÇÁÆ®¿þ¾î ¾÷µ¥ÀÌÆ® ½Ã Àû¿ë ¿¹Á¤(10¿ù)
    • AC Voltammetry (ACV)

    Pulsed techniques :

    • Differential Pulse Voltammetry (DPV)
    • Square Wave Voltammetry (SWV)
    • Normal Pulse Voltammetry (NPV)

    ÀÌ method µéÀº ¸ðµÎ trace analysis¿¡ Àû¿ëµÇ´Â stripping modes¿¡¼­ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.

    Amperometric techniques :

    • Chronoamperometry (CA)
    • Zero Resistance Amperometry (ZRA)
    • Chronocoulometry (CC)
    • MultiStep Amperometry (MA)
    • Fast Amperometry (FAM) * ´ÙÀ½ ¼ÒÇÁÆ®¿þ¾î ¾÷µ¥ÀÌÆ® ½Ã Àû¿ë ¿¹Á¤(10¿ù)
    • Pulsed amperometric detection (PAD)
    • Multiple pulse amperometry (MPAD) * ´ÙÀ½ ¼ÒÇÁÆ®¿þ¾î ¾÷µ¥ÀÌÆ® ½Ã Àû¿ë ¿¹Á¤(10¿ù)

    Galvanostatic techniques :

    • Linear Sweep Potentiometry (LSP)
    • Chronopotentiometry (CP)
    • MultiStep Potentiometry (MP)
    • Open Circuit Potentiometry (OCP)
    • Stripping Chronopotentiometry (SCP or PSA) * ´ÙÀ½ ¼ÒÇÁÆ®¿þ¾î ¾÷µ¥ÀÌÆ® ½Ã Àû¿ë ¿¹Á¤(10¿ù)

    Other :

    • Mixed Mode (MM)
    • Potentiostatic Impedance spectroscopy (PEIS)
         - Potential scan
         - Fixed potential
         - Time scan
    • Galvanostatic Impedance spectroscopy (PEIS) * ´ÙÀ½ ¼ÒÇÁÆ®¿þ¾î ¾÷µ¥ÀÌÆ® ½Ã Àû¿ë ¿¹Á¤(10¿ù)
         - Current scan
         - Fixed current
         - Time scan

     

    Software


    http://www.qrins.com/ckseo/palm/pic/EmStat4S_in_lab_with_PC.png

    PalmSens»çÀÇ ´Üä³Î Àåºñ´Â Windows ¿ë PSTrace ¿Í ÇÔ²² Á¦°øµË´Ï´Ù .

     

    Downloads