  • USB or Wireless Bluetooth connection
  • Potential range ¡¾5V or ¡¾8V (3+)
  • Current ranges 1 nA to 10 mA or 100 mA
  • Ideal for mobile sensor applications
  • Description

    Techniques

    Specifications

    Options

    Software

    Downloads

     

    Description

    EmStat Blue´Â ¿¬±¸ ¹× ±³À°¿ëÀ¸·Î »ç¿ë °¡´ÉÇÑ ÀÛÀº »çÀÌÁîÀÇ ±âº»Çü Potentiostat·Î  1 nA ~ 100 mA (EmStat3 +) Ç® ½ºÄÉÀÏÀÇ 8°³ Àü·ù ¹üÀ§¸¦
    °¡Áö¸ç ÃÖ¼Ò ºÐÇØ´ÉÀº 1 pAÀÔ´Ï´Ù.
    ±âº» ³»Àå ¹èÅ͸®°¡ Æ÷ÇԵǾî ÀÖ¾î º°µµÀÇ ¿ÜºÎ Àü¿ø °ø±Þ¾øÀÌ »ç¿ë °¡´ÉÇÏ¸ç ºí·çÅõ½º°¡ ³»ÀåµÇ¾î ÀÖ¾î Windows¿ë PSTrace ¼ÒÇÁÆ®¿þ¾î »Ó¸¸
    ¾Æ´Ï¶ó Android ¿ë PStouch appÀ¸·Îµµ Àåºñ Á¦¾î°¡ °¡´ÉÇÕ´Ï´Ù.

    Àåºñ¿¡ Screen Printed Electrode¿ë Ä¿³ØÅÍ°¡ ³»ÀåµÇ¾î ÀÖ¾î º°µµÀÇ ÄÉÀÌºí ¾øÀÌ ¹Ù·Î Àåºñ¿¡ ²È¾Æ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.
    (
    »ç¿ë °¡´ÉÇÑ ¼¾¼­ Àü±Ø – BVT, ItalSens, DropSens »ç Á¦Ç° µî)

    EmStat Blue ±¸¼ºÇ° :

    • °ß°íÇÑ Àåºñ ÈÞ´ë¿ë ÄÉÀ̽º 
    • 2mm ¹Ù³ª³ª Ä¿³ØÅÍ°¡ ´Þ·Á ÀÖ´Â °íÇ°ÁúÀÇ ÀÌÁß Â÷Æó ¼¿ ÄÉÀ̺í
    • ¾Ç¾îŬ¸³
    • ´õ¹Ì¼¿
    • USB ÄÉÀ̺í
    • PSTrace ¼ÒÇÁÆ®¿þ¾î

    ¾Ç¾î Ŭ¸³ÀÌÀÖ´Â ¼¾¼­ ÄÉÀ̺í

     

    Techniques

    EmStat Blue¿¡¼­ Áö¿øµÇ´Â Å×Å©´ÐÀº ´ÙÀ½°ú °°½À´Ï´Ù.

    Voltammetric techniques :

    • Linear sweep voltammetry (LSV)
    • Differential pulse voltammetry (DPV)
    • Square wave voltammetry (SWV)
    • Normal pulse voltammetry (NPV)
    • Cyclic voltammetry (CV)

    ÀÌ method µéÀº ¸ðµÎ trace analysis¿¡ Àû¿ëµÇ´Â stripping modes¿¡ »ç¿ëµÉ ¼ö ÀÖ½À´Ï´Ù.

    Techniques as a function of time :

    • Chronoamperometry (CA)
    • Pulsed amperometric detection (PAD)
    • Multiple pulse amperometry (MPAD)
    • Open Circuit Potentiometer (OCP))
    • Multistep amperometry (MA)

    Specifications

    EmStat ¹öÀü :

    3

    3+

    dc-potential range

    ¡¾ 3.000V

    ¡¾ 4.000V

    compliance voltage

    ¡¾ 5V

    ¡¾ 8V

    dc-potential resolution

    0.1 mV

    0.125 mV

    applied dc-potential accuracy

    0.2 % 
    with max. 2 mV offset error

    ¡Â 0.3 %
    with max. mV offset error

    current ranges

    1 nA ~ 10 mA (8 ranges)

    1 nA ~ 100 mA (9 ranges)

    maximum current

    ¡¾ 20 mA typical 
    and ¡¾ 15 mA minimum

    ¡¾ 100 mA typical

    Àü·ù´Â ZRA(zero resistance ammeter)¸¦ »ç¿ëÇÏ¿© ÃøÁ¤µË´Ï´Ù.

    current resolution

    0.1 % of current range, 1 pA at lowest current range

    current accuracy (deviation)

    ¡Â 1 % of current range at 1 nA 
    ¡Â 0.5 % at 10 nA 
    ¡Â 0.2 % at 100 nA to 100 uA 
    ¡Â 0.5 % at 1 mA, 10 mA and 100 mA 
    all with max. 0.2 % offset error

    electrometer amplifier input     

     > 100 Gohm // 4 pF

    rise time    

    approx. 100 ¥ìs

    sensor connection


    shielded cable with circular connector for
    WE, RE, CE and Sense (EmStat3+ only)

    EmStat Blue model

     

    housing

    anodized aluminium: 6.7 x 5.0 x 2.8 cm

    weight

    250 g

    power supply

    USB 
    5 V, min. 130 mA (ES3) or 500 mA (ES3+)

    Battery time

    > 8 hours with cell off
    > 6 hours with continuous cell on 1 uA current
    full charge takes approx. 3 hours

    communication

    mini USB or Bluetooth

    auxiliary port present

    yes

    external I/O options

    analog: 1 input 1 output channel
    (both 0 V – 4.096 V)
    digital: 1 input, 4 output lines
    (maximum rating: -0.3 V to 5.3 V)

     

    EmStat Standard vs EmStat Blue ºñ±³

    EmStat

    Standard

    Blue

    Å©±â

    6.7 x 5.0 x 2.8 cm

    10.0 x 6.0 x 3.4 cm

    ¹«°Ô

    85 g

    250 g

    ³»Àå¹èÅ͸® À¯/¹«

    ¾øÀ½

    ÀÖÀ½

    Åë½Å

    USB

    USB + Bluetooth

    º¸Á¶ Æ÷Æ®

    ¾øÀ½

    ÀÖÀ½

    ¼¾¼­ Ä¿³ØÅÍ

    LEMO

    LEMO + SPE

     

     Options

     

    Software

    http://www.palmsens.co.kr/img/windows_android.png

    PalmSens»çÀÇ ´Üä³Î Àåºñ´Â Windows ¿ë PSTrace ¿Í ÇÔ²² Á¦°øµË´Ï´Ù .
    ½º¸¶Æ® ¶Ç´Â ÅÂºí¸´À» »ç¿ëÇÏ¿© EmStat  Blue¸¦ Á¦¾îÇÏ·Á¸é Android ¿ë PStouch¸¦ ´Ù¿î·Îµå ÇϽʽÿÀ.  Google Play ½ºÅä¾î ¿¡¼­ ¹«·á·Î ´Ù¿î¹ÞÀ» ¼ö ÀÖ½À´Ï´Ù. 

     

    Downloads